Customization: | Available |
---|---|
Type: | Water-Cooled |
Cooling Method: | Water-cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The chiller adopts scroll compressor which consisting of 1 to 6. It matches up with the high efficiency shell and tube type condenser, evaporator and control System.
1.Multi-design: The unit has the cooling tower's condition, water source conditions and the ground source conditions, it can according to the users request to design.
2.High efficient and energysaving: It can save 30% to 40% running costs of the heating supply and refrigeration than the average air-conditioning running costs.
3.Multifunctional: It can supply heating, air-conditioning refrigeration, but also can provide hot water through a series system to achieve heating and cooling.
Types: 1) cooling tower condition type
2) underground water condition type
3) underground piping loop condition type
Ground source working condition R407C | |||||||||||||||
Model RLSW - (C) R | 7 | 10 | 12 | 15 | 18 | 12 | 15 | 18 | 20 | 28 | 30 | 35 | 40 | ||
Power supply | 220V/5OHZ | 380V/50HZ | |||||||||||||
Compressor Qty | 1 | ||||||||||||||
Normal cooling capacity | kW | 8.3 | 10.3 | 12.2 | 15.2 | 18 | 12.2 | 15.2 | 18 | 19.5 | 27.7 | 29.7 | 34.3 | 40.4 | |
Input power of cooling | kW | 1.8 | 2.2 | 2.6 | 3.2 | 3.4 | 2 | 2.8 | 3 | 3.4 | 5 | 5 | 6 | 7.2 | |
Norma heating capacity | kW | 9.4 | 12.4 | 14.2 | 17.8 | 20.1 | 12.4 | 17.8 | 20.1 | 21.4 | 29.7 | 31.7 | 38.3 | 45.1 | |
Input power of heating | kW | 2.4 | 2.9 | 3.5 | 4.3 | 4.8 | 2.8 | 3.9 | 4.1 | 4.9 | 6.7 | 6.7 | 8.2 | 9.8 | |
Max. running current | A | 15.5 | 17.5 | 21 | 27.1 | 30.5 | 7 | 9.1 | 9.6 | 11.7 | 15 | 15 | 18.8 | 22.2 | |
Cable diameter (Copper wire distnce≤20meters) |
mm2 | 2*4 | 2*4 | 2*4 | 2*6 | 2*6 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 34+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | |
Compressor type | Hermetic scroll | ||||||||||||||
Sarting mode | Direct | ||||||||||||||
Refrigerant | R22 / R407C | ||||||||||||||
Refrigerant charge | kg | 1.8 | 1.8 | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | 5 | 6 | 6 | 6.5 | 6.5 | |
Refrigerant control device | Thermostatic expansion valve | ||||||||||||||
Evaporator | Type | Plate type | Tube in tube type | ||||||||||||
Water pressure drop | kPa | 70 | |||||||||||||
Water pipe Dia. | DN | 25 | 25 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
Connection | Threaded connect | ||||||||||||||
Chilled water flow | m3/h | 1.4 | 1.8 | 2.1 | 2.6 | 3.1 | 2.1 | 2.6 | 3.1 | 3.4 | 4.8 | 5.1 | 5.9 | 6.9 | |
Well water flow | m3/h | 1.9 | 2.3 | 2.8 | 3.45 | 4.1 | 2.8 | 3.5 | 4.1 | 2 | 2.9 | 6.7 | 7.8 | 9.2 | |
Condenser type | Type | Plate type | Tube in tube type | ||||||||||||
Water pressure drop | kPa | 70 | |||||||||||||
Water pipe Dia. | DN | 25 | 25 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
Well water flow | m3/h | 1.9 | 2.3 | 2.8 | 3.5 | 4.1 | 2.8 | 3.5 | 41 | 2 | 2.9 | 6.7 | 7.8 | 9.2 | |
Hot water flow | m3/h | 1.4 | 1.8 | 2.1 | 2.6 | 3.1 | 2.1 | 2.6 | 3.1 | 3.4 | 4.8 | 5.1 | 5.9 | 6.9 | |
Dimensions | L | 1000 | 1000 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | |
W | 610 | 610 | 655 | 655 | 655 | 655 | 655 | 655 | 655 | 655 | 655 | 655 | 655 | ||
H | 730 | 730 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | ||
Natwnigt | kg | 100 | 100 | 210 | 210 | 210 | 210 | 235 | 235 | 235 | 235 | 270 | 270 | 270 | |
Running weigh | kg | 120 | 120 | 248 | 248 | 248 | 248 | 280 | 280 | 280 | 280 | 325 | 325 | 340 | |
Noise | dB(A) | 62 | 62 | 62 | 62 | 62 | 62 | 62 | 62 | 62 | 70 | 70 | 72 | 72 |
Ground source working condition R410A | |||||||||||||||
Model RLSW - (C) R | 7 | 10 | 12 | 15 | 18 | 12 | 15 | 18 | 20 | 28 | 30 | 35 | 40 | ||
Power supply | 220V/50HZ | 380V/50HZ | |||||||||||||
Compressor Qty | 1 | ||||||||||||||
Normal cooling capacity | kW | 8.3 | 10.3 | 12.2 | 15.2 | / | 12.2 | 15.2 | 18 | 19.5 | 27.7 | 29.7 | 34.3 | 40.4 | |
Input power of cooling | kW | 2 | 2.5 | 2.8 | 3.5 | / | 2.5 | 2.9 | 3.3 | 3.5 | 5 | 5.4 | 6.6 | 7.2 | |
Norma heating capacity | kW | 9.4 | 12.4 | 14.2 | 17.8 | / | 12.4 | 17.8 | 20.1 | 21.4 | 29.7 | 31.7 | 38.3 | 45.1 | |
Input power of heating | kW | 2.7 | 3.6 | 3.7 | 4.6 | / | 3.4 | 3.9 | 4.5 | 4.7 | 6.8 | 7.3 | 8.4 | 9.8 | |
Max. running current | A | 15.5 | 15.5 | 24.1 | 24.1 | / | 8 | 9.1 | 10.2 | 10.9 | 15.7 | 17 | 20 | 22.5 | |
Cable diameter (Copper wire distnce≤20meters) |
mm2 | 2*4 | 2*4 | 2*4 | 2*4 | / | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | |
Compressor type | Hermetic scroll | ||||||||||||||
Sarting mode | Direct | ||||||||||||||
Refrigerant | R410A | ||||||||||||||
Refrigerant charge | kg | 1.8 | 1.8 | 4.5 | 4.5 | / | 4.5 | 4.5 | 4.5 | 5 | 6 | 6 | 6.5 | 6.5 | |
Refrigerant control device | Thermostatic expansion valve | ||||||||||||||
Evaporator | Type | Plate type | Tube in tube type | ||||||||||||
Water pressure drop | kPa | 70 | |||||||||||||
Water pipe Dia. | DN | 25 | 25 | 50 | 50 | / | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
Connection | Threaded connect | ||||||||||||||
Chilled water flow | m3/h | 1.4 | 1.8 | 2.1 | 2.6 | / | 2.1 | 2.6 | 3.1 | 3.4 | 4.8 | 5.1 | 5.9 | 6.9 | |
Well water flow | m3/h | 1.9 | 2.3 | 2.8 | 3.5 | / | 2.8 | 3.5 | 4.1 | 4.4 | 4.3 | 6.7 | 7.8 | 9.2 | |
Condenser type | Type | Plate type | Tube in tube type | ||||||||||||
Water pressure drop | kPa | 70 | |||||||||||||
Water pipe Dia. | DN | 25 | 25 | 50 | 50 | / | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
Well water flow | m3/h | 1.9 | 2.3 | 2.8 | 3.5 | / | 2.8 | 3.5 | 4.1 | 4.4 | 6.3 | 6.7 | 7.8 | 9.2 | |
Hot water flow | m3/h | 1.4 | 1.8 | 2.1 | 2.6 | / | 2.1 | 2.6 | 3.1 | 3.4 | 4.8 | 5.1 | 5.9 | 6.9 | |
Dimensions | L | 1000 | 1000 | 1400 | 1400 | / | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | |
W | 610 | 610 | 655 | 655 | / | 655 | 655 | 655 | 655 | 655 | 655 | 655 | 655 | ||
H | 730 | 730 | 1100 | 1100 | / | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | ||
Natwnigt | kg | 100 | 100 | 210 | 210 | / | 210 | 235 | 235 | 235 | 235 | 270 | 270 | 285 | |
Running weigh | kg | 120 | 120 | 248 | 248 | / | 248 | 280 | 280 | 280 | 280 | 325 | 325 | 340 | |
Noise | dB(A) | 62 | 62 | 62 | 62 | / | 62 | 62 | 62 | 62 | 70 | 70 | 72 | 72 |
TIME OF DELIVERY : Within 25 days after receiving deposit
Support T/T , L/C, Alibaba
One year from shipping date
During the warranty period, machines which cannot run due to quality problems,Choose the following options.
1) During the one-year warranty period, non-human factors cause product quality problems, and provide parts replacement and repair and maintenance services.
2) In addition to the one-year warranty period, parts replacement and repair and maintenance services are provided at the user's expense.
1) Pay the full amount in one lump sum, 1% discount.
2) Recommend other customers to buy and return a part of the commission.
Q1: Are you a manufacturer?
A1: Yes, we have more than 11 years in water chiller business. Ruidong Group Co.,Ltd is a central air conditioning product design,production,sale,installation in one of the modern large-scale enterprises.Group registered capital of 155.5 million yuan,covers an area of three hundred thousand square meters,construction area of one hundred and eighty thousand square meters. Group is located in the beautiful garden city in northwestern Shandong Dezhou.Welcome to visit us anytime!
Q2: Could you help us to recommend the model for our project?
A2: Yes, we have engineer to check the details and make the scheme for you. Based on the following: Cooling capacity / Refrigerant / Ambient temperature / Voltage / For what industry /The building drawing(if you have) / Any other special requirements.
Q3: How to ensure your product with good quality?
A3: We use the well-know brand accessories, such as Hanbell, copeland, danfoss compressor, Emerson expansion Valve, Siemens controller. All chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q4:Pre-sales service
A4:
1.Quick response within .
2. hours. Various communication methods, email, phone or chat APP (WeChat/WhatsApp/linkin, etc.) are available.
3. Full technical information in English or Russian.
4. For the end user, HAVC design and drawings for project are offered online or on site free of charge.
Q5: After-sales service and guarantee
A5:
1. Report the order tracking status regularly, and provide real-time photos or videos if necessary.
2.Provide online installation and commissioning technical guidance, if necessary, can provide paid on-site commissioning services.
3. After-sales guarantee: 13 months for the main engine and 37 months for the compressor.
During the warranty period, if any quality defects, the accessories will be sent by us free of charge against detailed
descriptions and necessary videos&photos. The labor costs incurred in replacing the accessories will be deducted from the next order.
4. Overseas installation and maintenance partners have been signed in countries, welcome to choose.
Q6: How can I place an order?
A6: Contact us via made in China.