Customization: | Available |
---|---|
After-sales Service: | Spare Parts and Training |
Warranty: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The water cooled screw uses semi seal double screw type compressor, and the chiller using the single return route or the multi-loop design, the module is easy to maintain, putting the protect and control facility into the control box, the main engine's operating conditions shows by the computer monitor.
The unit assembling finishes in the factory, the products can leave the factory after running debugging. This series of chiller applicable scope includes: market, office, commercial building, factory workshop, guesthouse, hospital and civil construction facility.
R22 Dry type water source heat pump (1) | ||||||||||
Unit model | RLSG-R | 200 | 260 | 280 | 320 | 380 | 420 | 460 | 540 | 580 |
Nominal cooling capacity | kW | 210 | 256 | 279 | 328 | 389 | 420 | 458 | 554 | 580 |
Input power | kW | 38.2 | 45.5 | 50 | 56.7 | 65.8 | 71.4 | 78.7 | 94.2 | 96.4 |
Nominal heating capacity | kW | 230 | 284 | 310 | 356 | 416 | 454 | 499 | 598 | 612 |
Running current | A | 50.3 | 60.2 | 65.6 | 74.6 | 86.5 | 93.9 | 103.5 | 123.9 | 126.7 |
Max.running current | A | 107.9 | 130.1 | 141.8 | 160.9 | 186.6 | 203.4 | 222.7 | 266.7 | 272.3 |
Power voltage | 3N-380V-50HZ | |||||||||
Refrigerant | R22 | |||||||||
Refrigerant charge | 42 | 51 | 56 | 63 | 75 | 83 | 92 | 111 | 114 | |
Refrigerant control device | Electronic expansion valve (EXV) | |||||||||
Compressor Type | Type | Semi-hermetic screw | ||||||||
Qty | 1 | |||||||||
Evaporator | Type | Shell & tube type | ||||||||
Water pressure drop (kPa) | 70-90 | |||||||||
Water pipe Dia (DN) | 80 | 80 | 100 | 100 | 100 | 100 | 100 | 125 | 125 | |
Chilled Water (m3/h) | 36 | 44 | 48 | 56 | 67 | 72 | 79 | 100 | 98 | |
Well Water (m3/h) | 22 | 26 | 29 | 34 | 40 | 43 | 47 | 60 | 59 | |
Condenser Type | Type | Shell & tube type | ||||||||
Water pressure drop (kPa) | 70-90 | |||||||||
Water pipe Dia (DN) | 80 | 80 | 100 | 100 | 100 | 100 | 100 | 125 | 125 | |
Hot Water (m3/h) | 36 | 44 | 48 | 56 | 67 | 72 | 79 | 100 | 98 | |
Well Water (m3/h) | 22 | 26 | 26 | 34 | 40 | 43 | 47 | 60 | 59 | |
Noise | dB(A) | 78.4 | 79 | 79 | 79.6 | 80.4 | 81.5 | 83.1 | 84.2 | 85.2 |
Unit structure | Horizontal type | |||||||||
Dimensions | L | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3400 | 3400 |
W | 1300 | 1300 | 1300 | 1350 | 1350 | 1350 | 1350 | 1450 | 1450 | |
H | 1650 | 1650 | 1650 | 1650 | 1800 | 1800 | 1800 | 1800 | 1800 | |
Install dimension (mm) | L1 | 2230 | 2230 | 2230 | 2230 | 2230 | 2230 | 2230 | 2735 | 2735 |
W1 | 790 | 790 | 790 | 790 | 880 | 880 | 880 | 880 | 880 | |
Net weighit | kg | 1600 | 1650 | 1700 | 1700 | 1700 | 1900 | 2300 | 2400 | 2600 |
Runing weight | kg | 1900 | 2000 | 2100 | 2300 | 2450 | 2550 | 2850 | 2950 | 3200 |
R22 Dry type water source heat pump (1) | |||||||||
Unit model | RLSG-R | 640 | 720 | 820 | 960 | 1100 | 1260 | 1400 | 1600 |
Nominal cooling capacity | kW | 642 | 720 | 826 | 978 | 1109 | 1260 | 1430 | 1620 |
Input power | kW | 108.5 | 121.4 | 138.4 | 163 | 184.2 | 206.7 | 229.9 | 256.9 |
Nominal heating capacity | kW | 691 | 776 | 892 | 1050 | 1190 | 1340 | 1522 | 1706 |
Running current | A | 142.6 | 159.6 | 182 | 214.4 | 242.2 | 271.8 | 302.3 | 337.7 |
Max.running current | A | 306.8 | 343.6 | 390.6 | 460.5 | 520.3 | 588.8 | 654.5 | 714.1 |
Power voltage | 3N-380V-50HZ | ||||||||
Refrigerant | R22 | ||||||||
Refrigerant charge | 128 | 144 | 165 | 196 | 222 | 252 | 282 | 320 | |
Refrigerant control device | Electronic expansion valve (EXV) | ||||||||
Compressor Type | Type | Semi-hermetic screw | |||||||
Qty | 1 | ||||||||
Evaporator | Type | Shell & tube type | |||||||
Water pressure drop (kPa) | 70-90 | ||||||||
Water pipe Dia (DN) | 150 | 150 | 150 | 150 | 150 | 200 | 200 | 200 | |
Chilled Water (m3/h) | 110 | 124 | 142 | 168 | 191 | 217 | 246 | 279 | |
Well Water (m3/h) | 66 | 74 | 85 | 101 | 114 | 130 | 147 | 167 | |
Condenser Type | Type | Shell & tube type | |||||||
Water pressure drop (kPa) | 70-90 | ||||||||
Water pipe Dia (DN) | 150 | 150 | 150 | 150 | 150 | 200 | 200 | 200 | |
Hot Water (m3/h) | 110 | 124 | 142 | 168 | 191 | 217 | 246 | 279 | |
Well Water (m3/h) | 66 | 74 | 85 | 101 | 114 | 130 | 147 | 167 | |
Noise | dB(A) | 86.3 | 86.6 | 87.1 | 87.6 | 88.4 | 89.2 | 90 | 91 |
Unit structure | Horizontal type | ||||||||
Dimensions | L | 3500 | 3500 | 3500 | 3600 | 3600 | 4200 | 4200 | 4200 |
W | 1450 | 1500 | 1500 | 1600 | 1600 | 1640 | 1640 | 1700 | |
H | 1850 | 1850 | 1850 | 1950 | 1950 | 1900 | 1900 | 1900 | |
Install dimension (mm) | L1 | 2735 | 2735 | 2735 | 2735 | 2735 | 3435 | 3455 | 3435 |
W1 | 1300 | 1300 | 1300 | 1300 | 1300 | 1350 | 1350 | 1350 | |
Net weighit | kg | 2800 | 3100 | 3400 | 3700 | 4000 | 4300 | 4600 | 50200 |
Runing weight | kg | 3400 | 3800 | 4600 | 5200 | 5600 | 6000 | 6500 | 6900 |
1.Location: Dezhou city, Shandong province, near Beijing 2.Registered capital: $ 15 million
3.Employees: about 1000 employees, including 500 workers for production, 22 product engineers and 38 technicians for design or service, 350 talents for administration, sales and installation, etc.4.Certificate: ISO9001, ISO14001, CE, National First Class Certificate for design and installation. 5.Products: more than 30 series and more than 1000 models, including air / water chiller (with heat pumps), AHU, various fan coils, VRV, Rooftop unit, fans, valves, air conditioner for industry.6.Covers an area of 300,000 square meters.
One year from shipping date
During the warranty period, machines which cannot run due to quality problems,Choose the following options.1) Pay the full amount in one lump sum, 1% discount.
2) Recommend other customers to buy and return a part of the commission.
Q1: Are you a manufacturer?
A1: Yes, we have more than 11 years in water chiller business. Ruidong Group Co.,Ltd is a central air conditioning product design,production,sale,installation in one of the modern large-scale enterprises.Group registered capital of 155.5 million yuan,covers an area of three hundred thousand square meters,construction area of one hundred and eighty thousand square meters. Group is located in the beautiful garden city in northwestern Shandong Dezhou.Welcome to visit us anytime!
Q2: Could you help us to recommend the model for our project?
A2: Yes, we have engineer to check the details and make the scheme for you. Based on the following: Cooling capacity / Refrigerant / Ambient temperature / Voltage / For what industry /The building drawing(if you have) / Any other special requirements.
Q3: How to ensure your product with good quality?
A3: We use the well-know brand accessories, such as Hanbell, copeland, danfoss compressor, Emerson expansion Valve, Siemens controller. All chillers are factory tested under load conditions to ensure good quality and easy installation for users.
Q4:Pre-sales service
A4:
1.Quick response within .
2. hours. Various communication methods, email, phone or chat APP (WeChat/WhatsApp/linkin, etc.) are available.
3. Full technical information in English or Russian.
4. For the end user, HAVC design and drawings for project are offered online or on site free of charge.
Q5: After-sales service and guarantee
A5:
1. Report the order tracking status regularly, and provide real-time photos or videos if necessary.
2.Provide online installation and commissioning technical guidance, if necessary, can provide paid on-site commissioning services.
3. After-sales guarantee: 13 months for the main engine and 37 months for the compressor.
During the warranty period, if any quality defects, the accessories will be sent by us free of charge against detailed
descriptions and necessary videos&photos. The labor costs incurred in replacing the accessories will be deducted from the next order.
4. Overseas installation and maintenance partners have been signed in countries, welcome to choose.
Q6: How can I place an order?
A6: Contact us via made in China.